GCN Circular 26407

Subject
LIGO/Virgo S191213g: upper limits from AGILE-MCAL observations
Date
2019-12-13T07:56:24Z (5 years ago)
From
Claudio Casentini at INAF-IAPS <claudio.casentini@inaf.it>
F. Verrecchia (SSDC, and INAF/OAR), C. Casentini (INAF/IAPS), M. Tavani
(INAF/IAPS, and Univ. Roma Tor Vergata), M. Cardillo, G. Piano, A. Ursi
(INAF/IAPS), F. Lucarelli, C. Pittori (SSDC, and INAF/OAR), A. Bulgarelli,
V. Fioretti, N. Parmiggiani (INAF/OAS-Bologna), M. Pilia
(INAF/OA-Cagliari), F. Longo (Univ. Trieste, and INFN Trieste), report on
behalf of the AGILE Team:

In response to the LIGO/Virgo GW event S191213g at T0 = 2019-12-13
04:34:08.142 (UT), a preliminary analysis of the AGILE minicalorimeter
(MCAL) triggered data found no event  candidates within a time interval
covering -/+ 15 sec from the LIGO/Virgo T0.

At the T0, about 60% of the S191213g 90% c.l. localization region was
accessible to the AGILE MCAL.Three-sigma upper limits (ULs) are obtained
for a 1 s integration time at different celestial positions within the
accessible S191213g localization region, from a minimum of 1.8E-06 erg
cm^-2 to a maximum of 8.1E-06 erg cm^-2 (assuming as spectral model a
single power law with photon index 1.5).

The AGILE-MCAL detector is a CsI detector with a 4 pi FoV, sensitive in the
energy range 0.4-100 MeV. Additional analysis of AGILE data is in progress.